Skip to main content

How to Use Advanced Button Operations

Everyday operations such as wake-up, enrollment status, manual reporting, and restart are documented in 3.1 Button operations and LED status. The operations below are used less often.

1. Advanced Button Operations​

While the node is awake:

OperationResult
Hold for at least 10 seconds, then release when the red, green, and blue LEDs cycleRestores factory settings
5 quick clicksThe node enters sleep mode
8 quick clicksThe node enters Bootloader mode

2. When to Restore Factory Settings​

Factory reset is rarely required. After a restart, the device automatically clears the network. Restore factory settings only after changing infrequently used configuration, or when a firmware upgrade requires the protocol files stored on the device to be refreshed.

note

If a device already has a saved configuration, upgrading the firmware does not overwrite the stored LoRa region or enrollment configuration. Each unit ships with a fixed Region set during manufacturing. After a factory reset, the node returns to the not-enrolled state while keeping the shipping Region of its firmware.